-
-
-
-
AT 4000--Dynamometer test system with integrated simulation vehicle model
-
AT 4000--NVH test system for electric drive assembly of new energy vehicles
-
AT 4000--towed test system for electric drive assembly of new energy vehicles
-
AT 4000--New Energy Vehicle Electric Drive Assembly Performance Test System
-
RT 4000--precision reducer (RV/harmonic/planetary) transmission error test system
-
RT 4000--precision reducer (RV/harmonic/planetary) fatigue life test system
-
RT 4000--precision reducer (RV/harmonic/planetary) bending stiffness system
-
RT 4000--precision reducer (RV/harmonic/planetary) performance comprehensive test system
-
ET4900--DJ Motor Temperature Control System (Compressor mode)
-
ET4900--DJ Motor Coolant temperature Control System (external circulating water mode)
-
TDZ4C table low speed centrifuge
Application fields: medical health, medical inspection, cosmetic medical institutions, oral medical institutions, blood centers, blood stations and other fields.
Classification:
● Application field
Medical health, medical examination, cosmetic medical institutions, oral medical institutions, blood centers, blood stations and other fields.
● Product advantages
strong brain, personality separation
Can remember multiple sets of parameter Settings, microcomputer processor precise control, boot without repeated Settings;
9 speed +- speed/can be arbitrarily set up, down speed;
Equipped with instantaneous centrifugation and timing centrifugation functions;
A variety of rotor, adapter options.
Lower temperature rise, better sample activity protection
Unique air cooling exhaust design, 20min temperature rise < 10℃.
Speed detection and calibration is convenient
Equipped with speed measuring window, convenient speed correction and detection.
Smart display, easy to control
High definition screen display, speed, centrifugal force, temperature, time and other parameters at a glance;
Parameters can be modified without downtime.
Silent operation, no inductive separation
Has a soft brake function to effectively prevent sample resuspension, three-level shock absorption, low vibration, low noise.
Concerned about sample safety, more concerned about your safety
Double door cover electronic door lock, start to lock, equipped with emergency unlock;
Abnormal state protection function, overspeed, overcurrent, overvoltage, misoperation, unbalanced fault code sound prompt, to ensure the safety of users, samples and machines;
High quality steel body, built-in stainless steel explosion-proof protection inner sleeve, stainless steel centrifugal chamber, multi-layer protection, heavy insurance.
● Product technical parameters
|
Model |
TDZ4C |
| Max Speed |
5000rpm |
| Max RCF |
4220× g |
|
Max Capacity |
4× 100ml |
|
Speed Accuracy |
± 10rpm |
| Timer Range |
1s~99m59s |
|
Display mode |
LCD display |
|
Motor |
DC brushless |
| Noise |
≤ 55dB(A) |
| Full Noise |
210W |
|
Power Supply |
AC220V 50HZ 5A |
| Weight |
25Kg |
| Dimensions |
450× 370× 300mm (L× D× H) |
● Rotor parameters (optional 5mL/7mL adapter)
|
Number |
Name |
Maximum speed (r/min) |
Maximum centrifugal force (× g) |
Capacity (mL) | Inch (mm) |
|
NO.1 |
Angular rotor |
5000r/min |
3080xg |
12× 10mL |
Φ 16× 87 |
|
NO.2 |
Angular rotor |
5000r/min |
2540xg |
6× 15mL (for 5/7/10mL) |
Φ 16× 118 |
|
NO.3 |
Angular rotor |
5000r/min |
3080xg |
12× 15mL (for 5/7/10mL) |
Φ 16× 118 |
|
NO.4 |
Angular rotor |
5000r/min |
3280xg |
24× 15mL (for 5/7/10mL) |
Φ 16× 118 |
|
NO.5 |
Angular rotor |
5000r/min |
2520xg |
4× 50mL |
Φ 29× 106 |
|
NO.6 |
Horizontal disc + pipe rack |
4200r/min |
2760xg |
24× 5/7mL |
Φ 13× 95 |
|
NO.7 |
Horizontal disc + pipe rack |
4200r/min |
2760xg |
12× 10/15mL (for 5/7mL) |
Φ 16× 120 |
|
NO.8 |
Horizontal disc + pipe rack |
4200r/min |
2760xg |
6× 50mL |
Φ 29× 105 |
|
NO.9 |
Horizontal disc + pipe rack |
4200r/min |
2760xg |
4× 1× 100mL |
Φ 37× 124 |
Previous Page
-
-
Auto parts testing product line
-
AT 4000--Dynamometer test system with integrated simulation vehicle model
-
AT 4000--NVH test system for electric drive assembly of new energy vehicles
-
AT 4000--towed test system for electric drive assembly of new energy vehicles
-
AT 4000--New Energy Vehicle Electric Drive Assembly Performance Test System
-
Robot component testing product line
-
RT 4000--precision reducer (RV/harmonic/planetary) transmission error test system
-
RT 4000--precision reducer (RV/harmonic/planetary) fatigue life test system
-
RT 4000--precision reducer (RV/harmonic/planetary) bending stiffness system
-
RT 4000--precision reducer (RV/harmonic/planetary) performance comprehensive test system
-
-
Contact Informationcontact us
Contact Phone: 028-85737373 | Contact Email: cb@chengbang.cn | Contact Address: No. 1588, West Fifth Road, Chesheng, Longquanyi District, Chengdu
Copyright©Sichuan Chengbang Haoran Measurement and Control Technology Co., Ltd. | Powered by:CEglobal | SEO