Sichuan Chengbang Haoran Measurement and Control Technology Co., Ltd.
+
  • image/2b86e5a0-bbe1-4dd0-8bb0-08d0e45c61f3.jpg

NC-3 torque measuring instrument

Case Presentation

NC-3 Torque Measuring Instrument—Product Background

Overview:

NC-3 torque meter is used in conjunction with various range of magnetoelectric phase difference torque sensors (such as NJ torque sensors) to accurately measure the torque, speed and power of various power machinery.
NC-3 torque meter adopts high-speed digital signal processor (DSP) and large-scale programmable logic chip (CPLD) to form a simple and efficient data acquisition and processing system. The unique design and advanced surface mount technology greatly improve the reliability of the system The hardware has two-level watchdog function to ensure that the system can be reset in time when abnormal; the instrument supports forward and reverse two-way zeroing, single-point or multi-point zeroing. The communication function has been strengthened, you can choose RS232/485 or CAN communication mode to make the communication with the computer easier, flexible and fast. Can adapt to the habits and preferences of different software engineers. It can adapt to different industrial scenes.
The instrument uses a large-screen dot-matrix LCD display and a simple keyboard to provide a friendly man-machine interface.

Performance:

Torque measurement

Signal amplitude: effective value 0.2V-20V AC
Frequency range: 2Hz-100kHz
Input impedance: 10kΩ
Sampling time: 1ms-5s
Range: any
Measurement accuracy: correctly used with NJ sensor, accuracy ±0.1%F.S or ±0.2%F.S
Sleeve speed measurement

Signal amplitude: effective value 0.2V-20V, AC or unidirectional pulse
Frequency range: 2Hz-100kHz
Input impedance: 10kΩ
Sampling time: 1ms-5s
Measurement accuracy: ±0.5% below 50HZ, ±0.1%±1 word above 50HZ
Analog output​​​​​​​
D/A conversion accuracy: 12 bits
Voltage output: output impedance: 10Ω
Current output: load resistance: <300Ω
Switch input
Input low level: Open the input terminal to ground, or input 0V.
Input high level: Input voltage from the input terminal to the ground. The voltage level can be 5V, 12V, 24V, 48V, etc.
Switch output (relay contact capacity)
Withstand voltage: AC 250V
Current: 3A

NC-3 Torque Measuring Instrument—Physical Photo

NC-3 Torque Measuring Instrument-Main Application

​​​​​​​It is used for data acquisition and processing of magnetoelectric phase difference torque sensors of various ranges.